Fat Analyzing Systems

Conventional off-line analysis systems take representative samples that need to be prepared prior to analysis. Even with fast off-line analysis systems, this approach means the machines are non-productive for up to 15 minutes while waiting for results. With the GEA MultiTrack on-line continuous fat analysis, the results for fat, moisture and protein are available the moment production stops, minimizing delays. Based on these  results, an integrated standardization module calculates the amount of fat or lean needed to reach the required target. Versions available for mounting on machines (Twin), in pipelines (P) and Grinders (G). Measuring is continuously performed in the process, either in a mixer, grinder, screw conveyor or pipeline. The results can be used for batch quality control documentation as well as for standardization of a batch to a certain fat target. The  system is supplied with calibration for fresh or frozen pork and beef with a fat content from 4% to 65%. Other calibrations with fat range up to 85% are available as options. 


Showing 2 items:
Photo:
GEA AutoGrind with GEA MasterTrack
photo (multi):
Headline:
Short description (en):

GEA MasterTrack  

In-line analyzer for fat, content, for mixers, GEA AutoGrind 200 and GEA PowerGrind 280, uses X-ray measurement for immediate results, continuous process.

Read more:
linkContactForm2012:
VideoLink text new:
 
Awards:
Image with link:
mastertrack inside
Technical data
GEA MasterTrack works with X-rays to measure fat only.
Photo:
CFS MultiTrack
photo (multi):
Headline:
Short description (en):


GEA MultiTrack Twin 

In-line analyzer for fat, protein and moisture content, for GEA UniMix, GEA CombiGrind I, GEA CombiGrind 2500/250, GEA ScrewLoader 400 and larger screw conveyors, uses precision near-infrared technology for immediate results, continuous process. 


GEA MultiTrack P (Pipeline) 

Version of the GEA MultiTrack fat analyzer for mounting directly in pipelines. 


GEA MultiTrack G (Grinder) 

Version of the GEA MultiTrack fat analyzer for mounting directly on all GEA grinders (and some third-party grinders).


Read more:
linkContactForm2012:
PDF link:
VideoLink text new:
 
Awards:
Image with link:
MutliTrack
Technical data
MultiTrack uses near infrared to measure fat, protein and moisture

Engage with us

Logo for footer:
GEA_GR_S.jpg
Start date:
18.04.2013  -
Finish date:
30.05.2013
City:
Birmingham
Country:
United Kingdom
Logo for footer:
Fispal_Food_Service_logo.jpg
Exhibition name:
Start date:
25.06.2013  -
Finish date:
28.06.2013
City:
São Paulo
Country:
Brazil
Logo for footer:
Confitexpo_logo.jpg
Exhibition name:
Start date:
30.07.2013  -
Finish date:
02.08.2013
City:
Guadalajara
Country:
México
Logo for footer:
AGROPRODMASH_logo_2013.jpg
Exhibition name:
Start date:
07.10.2013  -
Finish date:
11.10.2013
City:
Mocow
Country:
Russia

Newsletter

gea-button-subscribe-newsletter.png